Respirator Fit Test Singapore: Quantitative and Qualitative Tests

Air Quality Meter

Several countries throughout the world now demand tight-fitting respirator fit testing. The Occupational Safety and Health Administration (OSHA) in the United States regulates when and how to fit testing should be performed. Fit-testing filtering facepieces, reusable respirators with cartridges and filters, and tight-fitting facepieces used with powered or supplied air systems are all examples. Fit testing is not necessary for loose-fitting respirators (e.g., hoods, helmets, and loose-fitting facepieces used with powered or supplied air respirators).

respirator fit test singapore is also conducted according to global standards by various government and private clinics.Workers in Singapore who need to use respirators at work must undergo a medical examination to determine their fitness to use respirators. Certain medical disorders, such as lung problems, may preclude workers from using respirators.

Qualitative Fit Test(QLFT)

Fit test methods are classified into several sorts. Qualitative fit test (QLFT) approaches rely on the test agent’s taste, odor, or discomfort. Isoamyl acetate, saccharin solution aerosol, BitrexTM (Denatonium Benzoate) solution aerosol, and irritating smoke are examples (stannic chloride).

Quantitative Fit Test (QNFT)

Methods of quantitative fit test (QNFT) generate a numerical assessment of respirator fit. Ambient aerosol condensation nuclei counter (e.g., PortaCount®Respirator Fit Tester) and regulated negative pressure are two examples (CNP). A third way, produced aerosol, is mostly utilized in laboratories and not so much by respirator users. The PortaCount® and CNP approaches, on the other hand, are more extensively employed.

When Is a Quantitative Fit Test (QNFT) Necessary?

Most types of tight-fitting respirators, including disposable filtering facepieces, can be fitted with either QLFT or QNFT. Tight-fitting facepieces used with powered or supplied air systems must be converted to a negative-pressure respirator using the appropriate cartridge or filter for the fit test method. When QNFT is required, there are a few exceptions:

  • When utilizing a full facepiece in negative-pressure air-purifying mode, an assigned protection factor (APF) of 50 is required (i.e., used with cartridges or filters). APF is the predicted degree of protection when utilized in conjunction with an effective respirator program that meets all relevant OSHA regulations (e.g., reduces inhalation exposure by a factor of 50).
  • In demand mode, a supplied-air respirator (SAR) or self-contained breathing apparatus (SCBA) is employed (uncommon and distinct from continuous flow or pressure-demand mode).
  • According to the National Fire Protection Association, if facepieces are used in SCBAs for structural firefighting.

When is a Qualitative Fit Test (QLFT) Administered?

  • Negative-pressure, air-purifying respirators are acceptable as long as they are only used in environments where the hazard is less than 10 times the permitted exposure limit (PEL).
  • Facepieces with a tight fit are used with powered and atmosphere-supplying respirators.

Both QLFT and QNFT are accepted by the US OSHA. There have been studies published on the benefits and drawbacks of QNFT. It should be noted that unless poor-fitting respirators were included in the analysis, there was little to no link between quantitative fit parameters and respirator performance. In other words, those who failed a quantitative fit test performed worse on respirators.